| Residential Builder "EFFICIENCY SMART PLUS" Home Program |
|
(Click builder for contact information)
Residential Builder "EFFICIENCY SMART PLUS" Home Program
Requirements
At least 1 or more of following building practices implemented:
- OUTSIDE WALLS UTILIZE: Blown Cellulose wet or dry or Polly-Foam filling exterior wall cavities or Concrete using 2" expanded styrene as forms for ABOVE & BELOW GRADE walls or equivalent properties.
- VARIABLE SPEED AIR HANDLED W/ 15 SEER HEAT PUMP
- HIGHER EFFICIENT ELECTRIC WATER HEATING - Utilizing Solar panel with electric water heater or Water Heater Heat Pump.
- LIGHTING: All recessed lights shall be in a self contained fixture with a zero clearance rating with a solid box covering the fixture if it is exposed in the attic. In addition, builder will provide CFL (Compact Fluorescent Light) bulbs for 25% of the lighting needs.
- ZERO EMISSIONS REFRIGERANT - Heat pump utilizes R-410 refrigerant. It is also controlled with a set back thermostat..
Return to energy efficient builders homepage
|
|
|
|